-40%

Portable laser tattoo removal machine Q switched yag laser eyebrow pigment spa

$ 306.23

Availability: 100 in stock
  • Color: White
  • Type: Q-Switched
  • Model: YT-1101
  • Items Included: Foot Pedal
  • Country/Region of Manufacture: China
  • Features: LCD Screen
  • Condition: New
  • Brand: Unbranded
  • All returns accepted: ReturnsNotAccepted
  • Manufacturer Warranty: 1 year

    Description

    International Buyers Please Note:
    a. Import duties, taxes and charges are not included in the item price or shipping charges. These charges are the buyer's responsibility.
    b. Please check with your country's customs office to determine what these additional costs will be prior to bidding/buying.
    Principle:
    The energy of Q-switched ND:YAG laser can be absorbed by the blue and black melanin.The melanin will be fragmented so small that they can be metabolized by the lymphatic system or egested out of the body. Thus the tattoo or other pigmentations will be removed without damage to normal tissue. The treatment is safe and convenient without downtime and side effects.
    Application:
    The system gem-adjusting Q switch can effectively curethe mixed pigments by pigment precipitation of extraneous source withpathological pigment change of endogenous source, inclusive of erroneous darkeyebrow-embroidery, lip-embroidery, lip-soak, eye line-embroidery, lip-line,tattoo (inclusive of tattoo by extraneous wounds), pigment precipitation bysensitive source, freckle on female\'s face (male\'s), coffee spot, old agespot, black mole, and birthmark in black, blue, purple, brown, red and etc.Treatment course for different illness case as follows:
    Treatments
    Treatment course required ( cure times)
    Treatment course interval
    Remark (requirements in surgery)
    eyebrow-embroidery(eyeliner grain)
    1 –2 times
    30-60 days
    Eyebrow blow, eyeball protection
    Eyebrow-embroidery ( eyeliner embroidery)
    1-3 times
    45-60 days
    Eyebrow blow,  eyeball protection
    Lip line (red dyed lip)
    1-3 times
    15-45 days
    Use 532nm filter
    Tattoo(caused by extraneous wounds)
    1-4 times
    30-60 days
    Blood infiltration will be fine on wounds
    Freckle, age spot
    1-4 times
    15-30 days
    Blood infiltration will be fine on wounds
    Birthmark, nevus/mole
    3-7 times
    45-90 days
    Must  have  Blood infiltration .
    (1
    )
    Treatmentfor tattoo in eyebrow
    Customer could not open eyes during treatment, operator should adjust energyaccording to depth of tattoo color, hold the handle and move it to treatmentarea slowly to make customer feel acceptable in mentally. Right now, the speedof flash could be set 3HZ, keep head of the handle a two-finger distance totreatment area, start treatment from head of eyebrow to end of eyebrow. It isneeded to treat again in 5-10 minutes if the color of tattoo re-appear.
    (2
    )
    Remove eye line
    The speed of flashes could be set 4-5HZ,adjust the energy of light to minimumenergy, keep a one-finger distance between head of handle and treatment area.Operator should strictly protect customers` eyes with panel for eyelid ormedical pledget (panel for eyelid)of 25px depth.
    Treatment should be started from down eye line, customer should deeply closeeyes and keep eyeball up-sight inside. Operator should press the pledget (panelfor eyelid) with forefinger and push up eyelid, peel down eyelid with middlefinger to bare the eye line, treat it with flashes of 4-5Hz. Then, treat up eyeline. Also customer should close eyes and keep eyeball down-sight inside.Operator should press the pledget (panel for eyelid) with middle finger andpush eyelid down, push eyelid up with forefinger to bare the eye line, treat itwith flashes of 4-5Hz.
    (3
    )
    Remove lip line
    The speed of flashes could be set 5Hz,keep a 3/4 finger distance between headof handle and treatment area. It is better to remove black, coffee, deep, redand brown lip line with 1064nm head at first time and then, treat again with532 nm head.
    Notice: All tattoos in lip should be treated in 6 months after making. ORremoval treatment will fail. It should have 45-60 days interval to continuenext treatment until remove all.
    (4
    )
    Remove tattoo
    The speed of flashes could be set 3Hz/5Hz.It is better to use high energy fortreatment until treatment area seeps a little blood. It should have 45-90 daysinterval to continue next treatment until remove all.
    (5
    )
    Remove spot and nevus
    The speed of flashes could be set 3Hz/5Hz.Keep 3-4 fingers distance betweenhead of handle and treatment area. It is better to use high energy fortreatment until treatment area seeps a little blood. It is advised to use 1064nm head for normal spot and nevus treatment, but for deep color spot and nevus,it is better to use 532nm head for treatment. It should have a 15-30daysinterval to continue next treatment until remove all.
    (6
    )
    Remove birthmark
    The speed of flashes could be set 3Hz/5Hz.It is better to use high energy fortreatment until treatment area seeps a little blood. It is advised to use1064nm head for birthmark treatment, but for red and deep color birthmark, itis better to use 532nm head for treatment. It should have 45-90 days intervalto continue
    Laser type
    Sapphire Q-Switch / YAG Laser
    Wave length
    wavelength 1064nm & 532nm &1320nm
    Width of pulse
    3.5-10ns
    Spots Size
    1-7mm
    Pulse energy
    20-2000mj
    Pulse rate
    1-10Hz
    Net weight
    20kg
    Voltage
    220V / 110V / 12A 50Hz(60Hz)
    Cooling system
    Wind + water
    2.Medical Laser Application Range:
    (1).For inner melanin:Nevus,coffee spot,age spot,skin pigmentation,Insdation spot,
    Toenail Fungus removal
    (2).For out source melanin:Tattoo on body,eye line and eyebrow line
    (3).Hair removal&Skin rejuvenation.
    4.Machine advantages:
    (1).
    7*3.7cm touch screen
    (2).
    Ceramic handle,avoid burnt that under long hours working
    (3).Sapphire cooling system ensures constantly working
    (4).
    1000W power and 2000mj energy
    (5)
    .Xenon lamp imported from Germany
    (6).Portable and aseismatic,convenient for transportation